Solved: A square footing of size B x B is required to carry a gross
Question A square footing of size B x B is required to carry a gross allowable load of 670 kN. The base of the footing is to be located at a depth of 1 m
Question A square footing of size B x B is required to carry a gross allowable load of 670 kN. The base of the footing is to be located at a depth of 1 m
Question Assume that the shear strength parameters of the soil are the same in the previous number, a square footing measuring BXB will be subjected to an allowable gross load of 1000KN with Fs =3
Question A square footing is 2x2m in plan. The soil supporting the foundation has a friction angle ϕ′=25∘,c′=20kN/m2,the unit weight of soil γ=16.5kN/m3. Determine the allowable gross load on the foundation using terzaghi bearing capacity
Assuming that the beam in Worked Example 1 is only laterally and torsionally restrained at the supports, determine whether a 356 × 171 × 51 kg m−1 UB section in S275 steel is still suitable?
The figure shows a simply supported beam and cantilever with uniformly distributed loads applied to it. Using grade S 275 steel and assuming full lateral restraint, select and check a suitable beam section. Solution